Weidmuller VPU AC II 3+1 300/50 2591080000
Protetores Sobretensão Weidmuller VPU AC II 3+1 300/50 2591080000
General ordering data
Dimensions and weights
Depth | 68 mm |
Depth (inches) | 2.677 inch |
Depth including DIN rail | 76 mm |
Height | 96.3 mm |
Height (inches) | 3.791 inch |
Width | 72 mm |
Width (inches) | 2.835 inch |
Net weight | 487 g |
Temperatures
Storage temperature | -40 °C…85 °C |
Operating temperature | -40 °C…85 °C |
Operating temperature, min. | -40 °C |
Operating temperature, max. | 85 °C |
Humidity | 5 – 95% rel. humidity |
Rated data UL
Ambient temperature (operational), max. | 85 °C |
Rated Voltage UN | 240 V |
VPR (N-PE) | 1,000 V |
MCOV (L-PE) | 300 V |
MCOV (N-PE) | 305 V |
SCCR | 150 kA |
In | 20 kA |
Category | SPD TYPE 1CA |
Ambient temperature (operational), min. | -40 °C |
Certificate No. (cURus) | E354261 |
MODE | all modes |
VPR (L-L) | 1,800 V |
VPR (L-N) | 900 V |
VPR (L-PE) | 1,000 V |
Voltage type | AC |
UL Energy Networks | 3-phase WYE, High-Leg Delta |
General data
Colour | black, orange, blue |
Design | Installation housing; 4TE, Insta IP 20 |
Operating altitude | ≤ 4000 m |
Optical function display | green = OK; red = arrester is defective – replace |
Protection degree | IP20 in installed state |
Rail | TS 35 |
Segment | Power distribution |
UL 94 flammability rating | V-0 |
Version | Surge protection |
Rated data IEC / EN
Combined pulse UOC | 6 kV |
Discharge current Imax (8/20µs) N-PE | 65 kA |
Discharge current Imax (8/20µs) wire-PE | 50 kA |
Discharge current In (8/20µs) N-PE | 40 kA |
Discharge current In (8/20µs) wire-PE | 20 kA |
Energy coordination (≤10 m) | Type II, Type III |
Follow-on current extinguishing capability Ifi | Follow current need not be taken into account |
Frequency range, max. | 60 Hz |
Frequency range, min. | 50 Hz |
Fuse | No Fuse neccessary ≤315 A gG, 250 A gG @50 kA Isccr, 315 A gG @25 kA Isccr |
Leakage current at Un | 1 µA |
Low voltage network | TN-C-S, TN-S, TT, IT with N, IT without N |
Mains voltage | 230 V / 400 V |
Max. continuous voltage, Uc (AC) | 300 V |
Max. continuous voltage, Uc (N-PE) | 305 V |
Number of poles | 4 |
Protection level Up at IN (L/N-PE) | ≤ 1.5 kV |
Protection level Up at IN (N-PE) | ≤ 1.5 kV |
Rated voltage (AC) | 230 V |
Requirements category acc. to IEC 61643-11 | Type II/III |
Requirements class, acc. to EN 61643-11 | T2, T3 |
Response time | ≤ 25 ns, ≤ 100 ns |
SPD type | T2, T3 |
Short-circuit current rating ISCCR | 50 kA |
Signalling contact | No |
Standards | IEC61643-11, EN61643-11, UL 1449 |
Temporary surge voltage (over-voltage) – TOV | 337 V |
Voltage type | AC |
Connection data
Stripping length | 15 mm |
Wire connection method | Screw connection |
Type of connection | Screw connection |
Stripping length, rated connection | 15 mm |
Tightening torque, min. | 2 Nm |
Tightening torque, max. | 4.5 Nm |
Clamping range, rated connection | 16 mm² |
Clamping range, min. | 4 mm² |
Clamping range, max. | 35 mm² |
Wire cross-section, solid, min. | 1.5 mm² |
Wire cross-section, solid, max. | 16 mm² |
Wire connection cross section, finely stranded, min. | 1.5 mm² |
Wire connection cross section, finely stranded, max. | 25 mm² |
Connection cross-section, stranded, min. | 1.5 mm² |
Connection cross-section, stranded, max. | 35 mm² |
Guarantee
Categoria: Desc. de Sobretensão EFAPEL
Não há avaliações ainda.